AT Command Set and S-Registers
14-173920-A2-GH30-40 October 1998
Table 14-3
(1 of 15)
392xPlus S-Registers
S-Register
Description
DCP LCD
Command
Sequence
S0 Auto-Answer Ring Number
1
. Register determines number of rings the modem
will count before automatically answering a call.
Enter zero (0) if you do not want the modem to automatically answer any calls.
Otherwise, enter a value from 1255 for the number of rings to count before
answering. The factory setting is 1.
Configure\Edit\
Line Dialer
S2 AT Escape Character. Register determines ASCII value used for escape
sequence to enter Command mode from Data mode.
Enter a value from 0 to 127 for the escape character. Any value greater than
127 causes the modem to disable the escape sequence. When the escape
sequence is disabled, the modem cannot return to Command mode until the
call is disconnected. The factory setting is 43 (+ key).
Configure\Edit\
DTE Dialer
S3 Carriage Return Character. Register determines ASCII value used as the
carriage return (Return key). This character is used to end command lines and
result codes.
Enter a value from 0 to 127 for the command end character. The factory
setting is 13 (carriage return key).
Configure\Edit\
DTE Dialer
S4 Line Feed Character. Register determines ASCII value used as the line feed
character.
Enter a value from 0127 for the line feed character. The factory setting is 10
(ASCII carriage return or line feed).
Configure\Edit\
DTE Dialer
S5 Backspace Character. Register determines ASCII value used as the
backspace (Backspace key). This character moves the cursor to the left and
erases the previous character.
Enter a value from 0127. The factory setting is 8 (backspace key).
Configure\Edit\
DTE Dialer
S6 Blind Dial Pause
1
. Register determines how long (in seconds) the modem
waits after going off-hook before dialing a telephone number if using result
code X0, X1, or X3.
Enter a value from 2255 seconds. The factory setting is 2.
Configure\Edit\
Line Dialer
S7 No Answer Timeout
1
. Register determines how long (in seconds) an
originating modem waits before abandoning a call when no answer tone is
received.
Enter a value from 1255 seconds. The factory setting is 45.
Configure\Edit\
Line Dialer
S8 , Pause Time for the Dial Modifier. Register determines how long (in
seconds) the modem pauses when it encounters a comma (,) in the Dial
command string.
Enter a value from 0255 seconds. The factory setting is 2.
Configure\Edit\
Line Dialer
S10 No Carrier Disconnect
1
. Register determines how long (in tenths of seconds)
the modem allows the carrier signal to be OFF before disconnecting the call.
Enter a value from 0254 in 0.1 second increments. A value of 255 disables
this register. The factory setting is 20 (2 seconds).
Configure\Edit\
Line Dialer
1
The range of allowable values may be restricted in some countries.